blob: 97ca0ba20990cd7080465a21cc26b4dafddb486d [file] [log] [blame]
# NXP SJA1000 configuration options
# Copyright (c) 2022 Henrik Brix Andersen <henrik@brixandersen.dk>
# SPDX-License-Identifier: Apache-2.0
config CAN_SJA1000
bool
help
This enables support for the shared NXP SJA1000 CAN driver.
config CAN_MAX_FILTER
int "Maximum number of concurrent active RX filters"
depends on CAN_SJA1000
default 5
range 1 32
help
As the NXP SJA1000 only supports one full-width RX filter, filtering of received CAN
frames are done in software.