| # Copyright (c) 2022 Würth Elektronik eiSos GmbH & Co. KG |
| # SPDX-License-Identifier: Apache-2.0 |
| |
| menuconfig WSEN_HIDS |
| bool "WSEN-HIDS humidity and temperature sensor" |
| default y |
| depends on DT_HAS_WE_WSEN_HIDS_ENABLED |
| select I2C if $(dt_compat_on_bus,$(DT_COMPAT_WE_WSEN_HIDS),i2c) |
| select SPI if $(dt_compat_on_bus,$(DT_COMPAT_WE_WSEN_HIDS),spi) |
| select HAS_WESENSORS |
| help |
| Enable driver for the WSEN-HIDS I2C/SPI-based humidity sensor with integrated |
| temperature sensor. |
| |
| if WSEN_HIDS |
| |
| choice WSEN_HIDS_TRIGGER_MODE |
| prompt "Trigger mode" |
| default WSEN_HIDS_TRIGGER_NONE |
| help |
| Specify the type of triggering to be used by the driver. |
| |
| config WSEN_HIDS_TRIGGER_NONE |
| bool "No trigger" |
| |
| config WSEN_HIDS_TRIGGER_GLOBAL_THREAD |
| bool "Use global thread" |
| depends on GPIO |
| select WSEN_HIDS_TRIGGER |
| |
| config WSEN_HIDS_TRIGGER_OWN_THREAD |
| bool "Use own thread" |
| depends on GPIO |
| select WSEN_HIDS_TRIGGER |
| |
| endchoice # WSEN_HIDS_TRIGGER_MODE |
| |
| config WSEN_HIDS_TRIGGER |
| bool |
| |
| config WSEN_HIDS_THREAD_PRIORITY |
| int "Thread priority" |
| depends on WSEN_HIDS_TRIGGER_OWN_THREAD |
| default 10 |
| help |
| Priority of thread used by the driver to handle interrupts. |
| |
| config WSEN_HIDS_THREAD_STACK_SIZE |
| int "Thread stack size" |
| depends on WSEN_HIDS_TRIGGER_OWN_THREAD |
| default 1024 |
| help |
| Stack size of thread used by the driver to handle interrupts. |
| |
| endif # WSEN_HIDS |