# TMP112 temperature sensor configuration options
# Copyright (c) 2016 Firmwave
# SPDX-License-Identifier: Apache-2.0
menuconfig TMP112
bool "TMP112 Temperature Sensor"
depends on I2C
help
Enable the driver for Texas Instruments TMP112 High-Accuracy Digital
Temperature Sensors.
The TMP102 is compatible with the TMP112 but is less accurate and has
been successfully tested with this driver.
if TMP112
config TMP112_NAME
string "Driver name"
default "TMP112"
help
Device name with which the TMP112 sensor is identified.
config TMP112_I2C_ADDR
hex "I2C address for TMP112"
default 0x48
help
I2C address of the TMP112 sensor.
0x48: A0 connected GND and A1 connected to GND.
0x49: A0 connected VDD and A1 connected to GND.
0x4A: A0 connected SDA and A1 connected to GND.
0x4B: A0 connected SCL and A1 connected to GND.
config TMP112_I2C_MASTER_DEV_NAME
string "I2C master where TMP112 is connected"
default "I2C_0"
help
Specify the device name of the I2C master device to which the
TMP112 chip is connected.
endif # TMP112