blob: 0752e2902d57320dd0da284b2fc549248668c878 [file] [log] [blame]
# Copyright 2024 NXP
# SPDX-License-Identifier: Apache-2.0
description: |
TI INA226 Bidirectional Current and Power Monitor.
The <zephyr/dt-bindings/sensor/ina226.h> file should be included in the
DeviceTree as it provides macros that can be used for initializing the
configuration registers.
compatible: "ti,ina226"
include: [sensor-device.yaml, i2c-device.yaml]
properties:
avg-count:
type: int
description: |
Number of samples to average (applies to all inputs).
Default is the power-on reset value.
default: 1
enum: [1, 4, 16, 64, 128, 256, 512, 1024]
vbus-conversion-time-us:
type: int
description: |
Vbus conversion time in microseconds.
Default is the power-on reset value.
default: 1100
enum: [140, 204, 332, 588, 1100, 2116, 4156, 8244]
vshunt-conversion-time-us:
type: int
description: |
Vshunt conversion time in microseconds.
Default is the power-on reset value.
default: 1100
enum: [140, 204, 332, 588, 1100, 2116, 4156, 8244]
operating-mode:
type: string
description: |
Selects mode of operation.
Default is the power-on reset value.
default: "Shunt and Bus, Continuous"
enum:
- "Power-Down (or Shutdown)"
- "Shunt Voltage, Triggered"
- "Bus Voltage, Triggered"
- "Shunt and Bus, Triggered"
- "Power-Down (or Shutdown)"
- "Shunt Voltage, Continuous"
- "Bus Voltage, Continuous"
- "Shunt and Bus, Continuous"
current-lsb-microamps:
type: int
required: true
description: |
Current LSB value in microAmpere.
This value gives the measurement resolution for current measurement.
Formula: current-lsb [μA] = maximum expected current [μA] / 2^15
Higher resolution means lower range of current measurement, vice versa.
For example, if maximum expected current is 15 [A]:
then, current-lsb [μA] = 15000000 [μA] / 2^15 ~= 457.763 [μA].
Note: rounded values may be used for convenience, e.g. 500uA/LSB.
rshunt-micro-ohms:
type: int
required: true
description: |
Shunt resistor value in micro-ohms.